| Model Number: | Pedestrian Crossing Controller |
|---|---|
| Body Material: | PC(Polycarbonate) Plastic |
| Feature: | Wireless Remoter+External Antenna |
| Power_Supply: | 12VDC Battery |
| power_consumption: | <0.2W/system |
Product Details
Basic Information:
| Product Size: | 240*135*75MM+215*110*50MM |
|---|---|
| power_consumption : | <0.2W/system |
| Drive_Current: | ≤8A/output |
| certificate: | CE+IP65 |
| Warranty: | 5 Years |
Product Details:
1000M Real-Time Wireless Communication By Remoter: 433MHz Frequency
PC(Polycarbonate) Plastic: 240*135*75MM+215*110*50MM For Small Size And Tough Use
5-Output And 2-Phase: 2 Phases For 2 Different Directions By 5 Outputs
Switch Working Mode: Expand From Standard 5-Output into 6-Output By Easy Setting
![]() |
![]() |
|---|---|
| 5-Output Wireless Solar Pedestrian Crossing Controller, NJGQ-XHJ-5-WXGJ12 | |
| Length: 240MM(Master/Slave)/215MM(Remotetr) | Handle Remoter For Wireless Operation |
| Width/Depth: 135MM(Master/Slave)/110MM(Remotetr) | 5-Output+2-Phase |
| Height:75MM(Master/Slave)/50MM(Remotetr) | 1000M Real-Time Wireless Communication |
5-Output Wireless Solar Pedestrian Crossing Controller is one type of our traffic controller system, which includes wire traffic controller and wireless traffic controller, as well as all connected traffic lights by wire or wireless.
Send your message to us
Controller channels and phase planning
Start with a channel schedule showing every lamp output and the movement it controls. An output count describes connection channels; it does not by itself define the number of junction approaches or a safe phase plan. Keep pedestrian calls, arrow movements and countdown interfaces explicit in the proposed wiring schedule.
Before selecting the controller, compare the lamp supply, load per channel and required switching arrangement with its terminal diagram. Provide the intended sequence, clearance intervals and any external inputs for review. Confirm the startup condition and fault response with the supplier and the project engineer before the unit is installed.
Wireless commissioning
Identify the coordinating unit and each remote unit on the site drawing. Confirm the pairing procedure, update behavior and defined response to a lost connection. Verify the link with the equipment in its actual operating positions; quoted radio reach should not replace an on-site communication check.
Details to confirm on the order
- Catalogue dimensions
- 240*135*75MM+215*110*50MM. Check the space needed for connections, installation and servicing as well as the outside dimensions. Confirm the supplied component and its connection drawing before integration.
- Published current reference
- ≤8A/output. Confirm the applicable load conditions and complete wiring diagram for the selected version before assigning connected equipment to its terminals.
Information for your enquiry
- Lamp quantity and electrical load connected to each output.
- Required stages, external inputs and any countdown communication.
- Terminal layout, cabinet space and the approved commissioning sequence.